- Product Categories
- Large walk-in environmental..
- Function integrated environ..
- Temperature and humidity en..
- Special environmental class..
- Mechanics test equipment
- A variety of industry-speci..
- Measuring Test Equipment
- Other reliability test equi..
- Laboratory overall planning..
- Friendly Links
Information Name: | UV aging chamber |
Published: | 2015-04-20 |
Validity: | 365 |
Specifications: | |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Product Details This series of equipment simulation sun dew harm caused to materials and products, widely used in weather-resistant properties of the material evaluation. Imported intelligent temperature and humidity control instrument for controlling temperature and humidity, with PID regulator, fast auto-tuning, you can set a variety of parameters, temperature and humidity direct digital display, reading is very convenient; high grade stainless steel liner material, the overall elegant appearance . Implementation of standards and test methods GB / T 16422.3, GB / T5170.9 GB / T 164423.3 ~ 1997 applicable to ASTM G154 Specifications Model WS-UV-1 / WS-UV-2 internal dimensions 45x110x50cm performance temperature range of room temperature 10 ℃ + 70 ℃ Temperature fluctuation ≤ ± 0.5 ℃ Humidity 95% ~ 100% RH Dimensions 50x130x148cm ambient temperature + 5 ℃ ~ + 35 ℃ test light UV-A / B test UV light source wavelength 280 ~ 400nm sample holder sample size 150x75x1.5cm and lamp center distance 50mm ± 2mm from the center of the lamp and the lamp 70mm ± 2mm brushed stainless steel material studio Senior High brushed stainless steel heated humidifier thermal and electric steam humidification system interface digital security smart touch key input ( programmable) operating mode programmed / constant setting range according to the Operating Temperature Range offline alarm input on the blackboard thermometer .PT-100 sensor subsidiary function, alarm display, timer function Standard accessories stainless steel sample holder 20 security configuration leakage, overload power outages protection, over-temperature protection, water, touchdown protection Power supply 220V ± 1%, 50HZ power three main technical parameters of the temperature range of 10 ℃ ~ + 70 ℃ (no light conditions) Notes: 1, both in the empty tank conditions (note except clear), according to GB / T5170 Test 2, air-cooled chamber system at room temperature 25 ℃ and under-ventilated conditions of test data; when 35 ℃ ≥ room temperature> 25 ℃, it can be used normally, but the low temperature range, cooling rate and thermal load capacity will be affected to some extent. 3, water-cooled chamber at temperature ≤28 ℃, pressure at 0.2MPa ~ 0.6MPa, under conditions out of the water pressure test data ≥0.2MPa temperature fluctuation ≤ ± 0.5 ℃ (no light conditions) Temperature uniformity ≤2 ℃ (no light conditions) temperature deviation ± 2 ℃ (no light conditions) Humidity 40% ~ 98% RH (non-light conditions) (see Figure humidity range) Humidity deviation + 2 ~ -3% (> 75% RH), ± 5% (≤75% RH) (no light conditions) heating time ≤60min (room temperature ~ + 70 ℃) light intensity (700 ~ 1120) ± 10% W / m2 (adjustable) illumination time adjustable 2 1 0 ~ 99h99min during the irradiation, the temperature of the test chamber should be close to a linear rate of rise in temperature and maintained at the set control value (typically set value + 55 ℃ and 40 ℃). According to the stop stage, the temperature of the test chamber should be close to a linear rate drops at a temperature control set value (typically set value + 25 ℃), keeping the temperature stable. Under different test procedures, the relationship between temperature, irradiation and time during the test is shown in Fig. 3 spectral energy distribution and Tolerance: should meet the requirements of Table 1 test time can be set within 0 ~ 999h, the following test procedures can automatically test: Test procedure A: to 24 hours for a cycle, irradiation 8 hours, stopping 16 photos hour test period can be set to the test procedure B: a 24-hour cycle, illuminated 20 hours, according to four hours to stop the test cycle can be set. Test procedure C: continuous irradiation, the test time can be set. Lamp cooling air-cooled (under normal conditions of use, the effective life of metal halide lamp 800 to 1000 hours) wind chamber wind speed is adjustable by inverter within 0.5 ~ 1.5m / s range; with the device attached manual wind speed and frequency device table. Spectral energy distribution and Tolerance: should meet the requirements of Table 1 (Figure 3) UV-B ultraviolet spectral region A visible-infrared bandwidth μm 0.28 ~ 0.32 0.32 ~ 0.40 0.40 ~ 0.52 0.52 ~ 0.64 0.64 ~ 0.78 0.78 ~ 3.00 radiation intensity W / m2 5 63,200,186,174,492 tolerance% ± 35 ± 25 ± 10 ± 10 ± 10 ± 20 |
Admin>>>
You are the 23073 visitor
Copyright © GuangDong ICP No. 10089450, Visto Tianjin Experimental Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 23073 visitor
Copyright © GuangDong ICP No. 10089450, Visto Tianjin Experimental Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility