Information Name: | Hebei and Beijing UV aging chamber, UV aging testing machine manufacturers |
Published: | 2015-05-13 |
Validity: | 360 |
Specifications: | |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Product Detail This series of equipment to artificial sunlight dew harm caused to materials and products, widely used for material weatherability performance evaluation. Imported intelligent temperature and humidity control instrument for controlling temperature and humidity, with PID regulation, fast auto-tuning, you can set a variety of parameters, temperature and humidity direct digital display, reading is very convenient; liner material Made of stainless steel material, the overall elegant appearance . The implementation of standards and test methods GB / T 16422.3, GB / T5170.9 GB / T 164423.3 ~ 1997 applicable to ASTM G154 Specifications Model WS-UV-1 / WS-UV-2 internal dimensions 45x110x50cm performance range of room temperature 10 ℃ + 70 ℃ Temperature fluctuation ≤ ± 0.5 ℃ Humidity 95% ~ 100% RH Dimensions 50x130x148cm Ambient temperature + 5 ℃ ~ + 35 ℃ test light source UV-A / B ultraviolet light source wavelength 280 ~ 400nm test sample holder sample size 150x75x1.5cm and lamp center distance 50mm ± 2mm from the center of the lamp and the lamp 70mm ± 2mm brushed stainless steel housing Advanced Materials Studio Advanced brushed stainless steel electric heating steam humidifiers and humidification thermal security system interface digital smart touch key input ( programmable) operating mode programmed / constant setting range according to the Operating Temperature Range Input offline alarm on board thermometer .PT-100 sensor subsidiary function, alarm display, timer function Standard accessories stainless steel sample holder 20 Security Configuration leakage, overload power protection, overtemperature protection, water, touchdown protection Power supply 220V ± 1%, 50HZ power 3 main technical parameters of the temperature range 10 ℃ ~ + 70 ℃ (no illumination) Notes: 1, were empty boxes under the conditions (Note except clear), according to GB / T5170 Test 2, air-cooled chamber system at room temperature 25 ℃ under well-ventilated conditions and test data; when 35 ℃ ≥ room temperature> 25 ℃, it can be used normally, but the low temperature range, cooling rate and thermal load capacity will be affected to some extent. 3, water-cooled chamber at temperature ≤28 ℃, the water pressure in 0.2MPa ~ 0.6MPa, under conditions out of the water pressure ≥0.2MPa test data temperature fluctuation ≤ ± 0.5 ℃ (no illumination) Temperature uniformity ≤2 ℃ (no illumination) Temperature deviation ± 2 ℃ (no illumination) Humidity range 40% ~ 98% RH (without illumination conditions) (see Figure humidity range) Humidity deviation + 2 ~ -3% (> 75% RH), ± 5% (≤75% RH) (no-light conditions) heating time ≤60min (room temperature ~ + 70 ℃) light intensity (700 ~ 1120) ± 10% W / m2 (adjustable) illumination time adjustable 2 1 0 ~ 99h99min during irradiation, the test chamber temperature should rise to close to a linear rate and maintained at the temperature control set value (typically set the value to + 55 ℃ and 40 ℃). According to the stop phase, the test chamber temperature should be close to a linear rate drops below the set temperature control values ??(typically set value + 25 ℃), and keep the temperature stable. Under different test procedures, the relationship between temperature, time of exposure and the test period is shown in Fig. 3 spectral energy distribution and Tolerance: Table 1 should meet the requirements of test time can be set within 0 ~ 999h, automatically according to the following test procedures were tested: Test Program A: In a 24-hour cycle, irradiation 8 hours, stop 16 photos hour test period can be set to test procedure B: a 24-hour cycle, illuminated 20 hours, stop according to four hours, the test cycle can be set. Test Procedure C: continuous irradiation, the test time can be set. Lamp cooling air-cooled (under normal conditions of use, the effective life of metal halide lamp 800 to 1000 hours) wind chamber wind speed adjustable by frequency converter in the 0.5 ~ 1.5m / s range; with the equipment specification attached wind speed and frequency device table. Spectral energy distribution and Tolerance: should meet the requirements of Table 1 (FIG. 3) UV-B ultraviolet spectral region A visible infrared Bandwidth μm 0.28 ~ 0.32 0.32 ~ 0.40 0.40 ~ 0.52 0.52 ~ 0.64 0.64 ~ 0.78 0.78 ~ 3.00 radiation intensity W / m2 5 63200186174492 tolerance% ± 35 ± 25 ± 10 ± 10 ± 10 ± 20 WISELY Tianjin Experimental Instrument Technology Co., Ltd. Tel: 4000-166-872 Tel: 022-22910499 Fax: 022-22910498 complaints Tel: 18622500837 E-mail: sales@chinaweisi.com Company Website: http: //www.chinaweisi.com Address: Wuqing branching sell 西肖 town village industrial zone on the 1st |
Admin>>>
You are the 23073 visitor
Copyright © GuangDong ICP No. 10089450, Visto Tianjin Experimental Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 23073 visitor
Copyright © GuangDong ICP No. 10089450, Visto Tianjin Experimental Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility